Joint Sealing

The vast majority of industrial gutters are manufactured from galvanised steel which are bolted or riveted together usually at 3 metre intervals and then sealed with mastic.

Over the years the joint sealant deteriorates causing the joints to leak. These joints can easily and effectively be repaired by cleaning the joint and applying a primer and a new coat of sealant.

If the gutters have been vinyl lined the joints may be repaired by using new vinyl patches or a more economical option would be to apply torch-on felt patches to the defective areas.

 

Gutter Surface Treatments

Galvanised steel will over time start to corrode causing the gutters to rust, flake and eventually perforate. If left, this corrosion will degrade to such an extent that the gutters will need to be plated prior to any works, or in the worst case be replaced.

Most gutter surface treatments are determined by both the condition of the gutters and the longevity required. For example if you lease your building you may only require a treatment that will last for five years; however should you own the building you may require a guaranteed fifteen year treatment.

We have various alternative treatments to suit your requirements and only in the worst case situations would recommend a bespoke gutter lining system.

 

Specifications

  1. A two coat bitumen treatment inclusive of a red oxide primer and joint sealant – no guarantee provided, but it is a proven cost effective treatment that is likely to last between 2 to 3 years, but it is weather sensitive
  2. A two coat mastic treatment - no guarantee provided, but it is a proven cost effective treatment that is likely to last between 3 to 5 years and is not weather sensitive
  3. A three coat system incorporating a mastic treatment with a fabric reinforcement layer which has a 5 year guarantee and is not weather sensitive
  4. A re-inforced acrylic polymer 3 coat system which has a 15 year guarantee, but it is weather sensitive
  5. Unifold Gutter Lining – a bespoke lining system with a 20 year guarantee and is not weather sensitive
 

request a callback





UK Gutter Maintenance Ltd.

Unit 7B, Easton Way
Colburn
Catterick Garrison
North Yorkshire DL9 4GA

Tel:
01748 835454
Fax:
01748 835473
Email:
This e-mail address is being protected from spam bots, you need JavaScript enabled to view it
Get In Touch

For further information, to arrange a site survey, inspection visit
or professional appraisal of your property, please contact us on
01748 835 454 or email This e-mail address is being protected from spam bots, you need JavaScript enabled to view it

 

CHAS - contractors health and safety assessment scheme Constructionline Approved eurosafe solutions - fall protection safe contractor approved
site by changinghorizon